Hitachi Healthcare Americas

ProSound Alpha 7 for Breast Surgery

ProSound Alpha 7 Overview

Recognized for our outstanding image quality, outstanding system reliability and intuitive use of cutting edge technology, Hitachi Healthcare remains the standard in the field of Breast Surgery.

Hitachi Healthcare’s premium level systems provide:

  • Real-Time Elastography with quantitative assessment tools
  • Extraordinary high-resolution digital imaging with specifically designed breast surgery transducers
  • Real-time imaging that immediately provides valuable information necessary to assist in surgical planning and execution
  • Guidance of biopsy procedures for more accurate placements of needles
  • Instant feedback on tumor margin delineation
  • Valuable information to guide tumor resections
  • Assistance in achieving complete tumor resection
  • Ability to visualize and account for blood flow
  • Minimally invasive micro-surgery imaging
  • Robotic surgery imaging
  • Localization and orientation of relative anatomy
  • Blending and overlaying of CT/MR images with ultrasound
ProSound Alpha 7 Compound Pulse Wave Generator (CPWG) ProSound Alpha 7 Compound Pulse Wave Generator (CPWG) ProSound Alpha 7 Broadband Harmonics™ (BbH) Click image to enlarge ProSound Alpha 7  Adaptive Image Processing (AIP) Click image to enlarge ProSound Alpha 7 Spatial Compound Imaging (SCI) ProSound Alpha 7 Image Optimizer Image Optimizer OFF ProSound Alpha 7 Image Optimizer Image Optimizer ON ProSound Alpha 7 Overview ProSound Alpha 7SmartProbes

ProSound Alpha 7 Image Technology

Clear images and advanced functions are what you have come to expect from Hitachi – Aloka. Our 60 years of experience and innovation continues with the ProSound Alpha 7 platform.

  • Overview
  • Compound Pulse Wave Generator (CPWG) – The most advanced broadband beam-forming technology combined with high speed image processing that allows for higher definition ultrasound imaging than ever before.
  • Broadband Harmonics™ (BbH) – Provides high quality imaging using an expanded range of harmonic signals. This technology results in excellent image resolution and sensitivity and improved penetration.
  • Adaptive Image Processing (AIP) – Clearly displays differences in tissues, reducing speckle noise while maintaining the frame rate. It can also display outlines more clearly by selectively emphasizing boundaries.
  • Spatial Compound Imaging (SCI) – The ultrasound beam is transmitted and received in real time and in the multiple directions resulting in a reduction of speckle noise, suppression of artifacts, and improvement of contrast resolution allowing lesions to be clearly observed.
  • Image Optimizer – At the touch of a button the B-mode image is instantly optimized to the user’s preference. This technology continually monitors the user’s typical settings to optimally adjust the image when pressed resulting in less manual adjustments and more efficient examinations.
  • SmartProbes – The new high-efficiency probes are very lightweight and designed to be high in energy conversion to transmit high-quality ultrasound beams.

Hitachi Healthcare’s commitment and dedication to breast surgery allows us to offer a wide range of consoles and specifically designed transducers to meet the needs of every breast surgeon.

Transducers ASU-1013 ASU-1013 - 3D Linear Transducer UST-5542 Linear Probes UST-5550-R UST-5550-R - Robotic Transducer UST-533 UST-533 - Micro-Surgery Transducer
ProSound Alpha 6 Ergonomics

ProSound Alpha 7 Ergonomics

The ProSound Alpha 7 utilizes a user-friendly universal design for multiple user operation that supports speedy examinations and scanning comfort.

  • User-customizable panel switches
  • Blue LED switches helpful to those with deuteranopia
  • Frequently used keys are arranged around a trackball
  • Images can be easily frozen thanks to integration of the gain knob and freeze switch
  • Menu items can be arranged to individual likings on the large (10.4 inches) LCD touch panel
  • Virtual keyboard for touch panel entries
  • Retractable keyboard stored under the operation panel
  • The control panel can be turned horizontally and is height adjustable
  • The most compact and lightest weight in its class allowing for good portability
  • Up to three probe holders can be mounted on each side of the console (holders on left side are optional)
ProSound Alpha 6 Ergonomics ProSound Alpha 6 Ergonomics

ProSound Alpha 7 Features

Real-time Tissue Elastography

An innovative diagnostic tool that provides real-time color display of tissue elasticity.

Real-time Tissue Elastography

D-eFLOW

Displays blood flow with directional information at higher frame rates and spatial resolution compared to conventional methods. Detail and accuracy of blood flow information is greatly increased with reduced blooming of color.

Brain Tumor with Blood Flow

Dual Dynamic Display (DDD)

Real-time side-by-side display of a B-mode image and Color Doppler image assisting in easy anatomical interpretation of blood flow.

Dual Dynamic Display (DDD)

Trapezoid

Trapezoidal display on linear transducers provides a wider diagnostic field of view.

Trapezoid OFF Trapezoid ON

High-Definition Extended Field of View (HD-EFV)

Provides an extended field-of-view image created from a series of real-time images. As the user moves the transducer across the area of interest a larger image is created that provides clearer spatial relationship information of anatomy and structures. This is especially helpful in assessing structures that are larger than the transducer field of view.

High-Definition Extended Field of View (HD-EFV)

Contrast Harmonic Echo (CHE) *

To improve understanding of blood flow information, Hitachi-Aloka offers harmonics enhanced imaging specifically designed for use with contrast agents. The low MI contrast imaging obtained improves signal-to-noise ratio.

* In the USA, contrast-enhanced ultrasound has not been market cleared by the FDA for all imaging applications.

Breast Imaging

ProSound Alpha 7 - Breast

Breast

ProSound Alpha 7 - Breast Elastography

Breast Elastography

ProSound Alpha 7 - Breast Solid Lesions

Breast Solid Lesions

ProSound Alpha 7 - Breast Solid Lesion

Breast Solid Lesion

ProSound Alpha 7 - Breast Elastography

Breast Elastography

ProSound Alpha 7 - Breast Solid Lesion

Breast Solid Lesion

ProSound Alpha 7 - Breast Multislice

Breast Multislice

ProSound Alpha 7 - Breast MPR

Breast MPR

ProSound Alpha 7 - Breast Cysts

Breast Cysts

ProSound Alpha 7 - Breast 3DMultislice

Breast 3DMultislice

ProSound Alpha 7 - Breast Cysts

Breast Cysts

ProSound Alpha 7 - Breast Solid Lesion

Breast Solid Lesion

ProSound Alpha 7 - Breast

Breast

Contact Info

Sales: 1-800-800-3106
Email: Sales_US@HitachiHealthcare.com